    Brand Name : GSKA
    Model Number : JP-P250HE
    Price : Negotiable
    Delivery Time : 3-5 days on receipt of official sales contract
    Payment Terms : L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
    Supply Ability : 500 pieces per Month
    • Product Details
    • Company Profile

    Three Phase Ratings Genset Diesel Generator , 3 Pole MCCB

    1, Generating Set Model:P250HE

    2, Engine Make & Model:Perkins 1306-E87TA300

    3,Alternator Model:LL5014H

    3, Circuit Breaker Type:3 Pole MCCB

    4, Frequency:50 Hz / 60 Hz

    5,Cycle: 4 Stroke

    6, Engine Speed:1500 rpm / 1800 rpm

    7, Cooling Method: Water

    8, Governing Type: Electronic

    9, Output Type: AC Three Phase

    10,Base Frame Type:Heavy Duty FabriCAT-parts-partsed Steel

    Three Phase Ratings Genset Diesel Generator , P250HE


    Output Ratings

    Generating Set Model

    * P250HE Prime* Standby*

    380-415V, 50 Hz

    230.0 kVA 250.0 kVA

    184.0 kW 200.0 kW

    480V, 60 Hz

    245.0 kVA 269.0 kVA

    196.0 kW 215.2 kW

    • Refer to ratings definitions on page 4.

    Ratings at 0.8 power factor.



    Technical Data

    Engine Make & Model:

    Perkins 1306-E87TA300

    Alternator Model:

    LL5014H

    Base Frame Type:

    Heavy Duty FabriCAT-parts-partsed Steel

    Circuit Breaker Type:

    3 Pole MCCB

    Frequency:

    50 Hz 60 Hz

    Engine Speed: RPM

    1500 1800

    Fuel Tank Capacity: litres (US gal)

    350 (92.5)

    Fuel Consumption: P230H l/hr (US gal/hr)

    48.7 (12.9) 55.3 (14.6)

    Fuel Consumption: P250HE l/hr (US gal/hr)

    52.6 (13.9) 61.4 (16.2)

    P230H / P250HE


    Engine Technical Data


    Physical Data

    Manufacturer: Perkins

    Model: 1306-E87TA300

    No. of Cylinders/Alignment: 6 / In Line

    Cycle: 4 Stroke

    Induction: Turbocharged Air To Air Charge Cooled

    Cooling Method: Water

    Governing Type: Electronic

    Governing Class: ISO 8528 G2

    Compression Ratio: 16.9:1

    Displacement: l (cu.in) 8.7 (530.9)

    Bore/Stroke: mm (in) 116.6 (4.6)/135.9 (5.4)

    Moment of Inertia: kg m² (lb. in²) 1.54 (5266)

    Engine Electrical System:

    -Voltage/Ground: 24/Negative

    -Battery Charger Amps: 45

    Weight: kg (lb)

    - Dry: 671 (1479)

    - Wet: 698 (1539)


    Air System


    Air Filter Type: Replaceable Element

    Combustion Air Flow:

    m³/min (cfm) -Standby: 16.9 (597) 23.5 (830)

    -Prime: 17.6 (622) 24.0 (848)

    Max. Combustion Air Intake

    Restriction: kPa (in H2O) 6.2 (24.9) 6.2 (24.9)

    Radiator Cooling Air Flow:

    m³/min (cfm) 324.0 (11442) 414.0 (14620)

    External Restriction to

    Cooling Air Flow: Pa (in H2O) 125 (0.5) 125 (0.5)


    Cooling System


    Cooling System Capacity:l (US gal) 9.8 (10.5) 39.8 (10.5)

    Water Pump Type: Centrifugal

    Heat Rejected to Water & Lube Oil: kW (Btu/min)

    -Standby: 101.3 (5761) 118.6 (6745)

    -Prime: 93.8 (5334) 109.2 (6210)

    Heat Radiation to Room:kW (Btu/min)

    -Standby: 58.5 (3327) 66.8 (3799)

    -Prime: 51.0 (2900) 59.0 (3355)

    Radiator Fan Load: kW (hp) 7.0 (9.4) 12.0 (16.1)

    Cooling system designed to operate in ambient conditions up to 50°C (122°F).

    Contact your local FG Wilson dealer for power ratings at specific site conditions.


    Performance


    Engine Speed: RPM 1500 1800

    Gross Engine Power: kW (hp)


    -Standby: 224.0 (300.0) 242.5 (325.0)

    -Prime: 205.5 (276.0) 223.5 (300.0)


    BMEP: kPa (psi)

    -Standby: 2058.0 (298.5) 1857.0 (269.3)

    -Prime: 1888.0 (273.9) 1711.0 (248.2)

    Regenerative Power: kW 20.8 28.6


    LubriCAT-parts-partsion System


    Oil Filter Type: Spin-On, Full Flow

    Total Oil Capacity l (US gal): 26.4 (7.0)

    Oil Pan l (US gal): 22.7 (6.0)

    Oil Type: API CG4 15W-40

    Cooling Method: Water


    Exhaust System


    Silencer Type: Level 1

    Silencer Model & Qty: SD100 (1)

    Pressure Drop Across

    Silencer System: kPa (in Hg) 8.70 (2.569) 8.70 (2.569)

    Silencer Noise Reduction

    Level: dB 12 10

    Max. Allowable Back

    Pressure: kPa (in. Hg) 10.7 (3.2) 10.7 (3.2)

    Exhaust Gas Flow:m³/min (cfm)

    -Standby: 44.5 (1572) 58.1 (2052)

    -Prime: 45.9 (1621) 59.2 (2091)

    Exhaust

    Gas Temperature: °C (°F) m³/min (cfm)

    -Standby: 508 (946) 447 (836)

    -Prime: 480 (895) 431 (808)


    Fuel System


    Fuel Filter Type: Replaceable Element Recommended Fuel: Class A2 Diesel

    Fuel Consumption: l/hr (US gal/hr)

    110% 100% 75% 50%

    Load Load Load Load


    50 Hz 52.6 (13.9) 48.7 (12.9) 37.6 (9.9) 26.8 (7.1)

    60 Hz 61.4 (16.2) 55.3 (14.6) 41.1 (10.9) 29.3 (7.7)


    P250HE

    50 Hz 52.6 (13.9) 40.4 (10.7) 28.6 (7.6)

    60 Hz 61.4 (16.2) 45.0 (11.9) 31.5 (8.3)


    (based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)

    P230H / P250HE


    Alternator Performance Data



    Data Item

    50 Hz 60 Hz

    415/240V

    400/230V

    230/115V

    200/115V

    380/220V

    220/110V

    220/127V

    480/277V

    240/139V

    380/220V

    220/110V

    240/120V

    208/120V

    230/115V

    440/254V

    220/127V

    Motor Starting Capability* kVA

    495

    465

    425

    546

    543

    362

    425

    397

    468

    Short Circuit Capacity** %

    300

    300

    300

    300

    300

    300

    300

    300


    Reactances: Per Unit

    Xd X'd X''d

    2.780

    0.130

    0.080

    3.000

    0.140

    0.086

    3.320

    0.160

    0.095

    2.320

    0.110

    0.066

    2.660

    0.130

    0.076

    4.210

    0.200

    0.121

    3.540

    0.170

    0.101

    3.830

    0.180

    0.110

    3.170

    0.150

    0.091


    Reactances shown are applicable to prime ratings

    • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

    ** With optional Permanent Magnet generator or AREP excitation.


    Alternator Technical Data


    Physical Data Operating Data


    Manufacturer: FG WILSON


    Overspeed:RPM 2250

    Model: LL5014H

    Voltage Regulation

    (steady state) (%):+ /- 0.5

    No. of Bearings: 1

    Wave Form NEMA = TIF: 50

    Insulation Class: H

    Wave Form IEC = THF: 2.0%

    Winding Pitch Code: 2/3 - 6

    Total Harmonic Content LL/LN:4.0%

    Wires: 12

    Supression is in line with European Standard

    Radio Interference: EN61000-6

    Ingress Protection Rating: IP23

    Radiant Heat: kW (Btu/min)

    -50 Hz: 17.2 (978)

    -60 Hz: 18.1 (1029)

    Excitation System: SHUNT

    AVR Model: R448

    P230H / P250HE


    Technical Data


    3 Phase Ratings and Performance at 50 Hz, 1500 RPM


    3 Phase Ratings and Performance at 60 Hz, 1800 RPM




    Voltage Prime Model Standby Model Voltage Prime Model Standby Model

    P230H P250HE P230H P250HE


    kVA kW

    kVA kW


    kVA kW

    kVA kW

    415/240V

    230.0 184.0

    250.0 200.0

    480/277V

    245.0 196.0

    269.0 215.2

    400/230V

    230.0 184.0

    250.0 200.0

    220/127V

    245.0 196.0

    268.0 214.4

    380/220V

    230.0 184.0

    250.0 200.0

    380/220V

    245.0 196.0

    265.0 212.0

    230/115V

    230.0 184.0

    250.0 200.0

    240/120V

    245.0 196.0

    267.0 213.6

    220/127V

    215.0 172.0

    240.0 192.0

    230/115V

    245.0 196.0

    267.0 213.6

    220/110V

    230.0 184.0

    250.0 200.0

    440/254V

    245.0 196.0

    266.0 212.8

    200/115V

    230.0 184.0

    250.0 200.0

    220/110V

    245.0 196.0

    265.0 212.0




    208/120V

    245.0 196.0

    268.0 214.4




    230/115V

    245.0 196.0

    267.0 213.6



    Definitions

    Standby Rating


    These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).



    Prime Rating


    These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.



    Standard Reference Conditions


    Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.




    Weights and Dimensions


    Weights: kg (lb) Dimensions: mm (in)

    Net (+ lube oil)

    2100 (4630)

    Length

    2960 (116.5)

    Wet (+ lube oil & coolant)

    2137 (4711)

    Width

    1003 (39.5)

    Fuel, lube oil & coolant

    2432 (5362)

    Height

    1718 (67.6)



    General Data


    Documents


    A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.



    Generating Set Standards


    The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.



    Warranty


    All equipment carries full manufacturer's warranty.


    Quality Three Phase Ratings Genset Diesel Generator , 3 Pole MCCB for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong ALI Testing Equipment Co,.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)